For coatings that require high-pressures – applies up to 2.8 gal (10.6 liters) per minute.
What a hydraulic system can do for you:
Graco's line of hydraulic Reactors brings increased yield and high output spraying. Ideal for in-plant OEM's or applicators that spray at high volumes.
Reactor 2 stand-alone models are available in an H-XP2 and H-XP3.
Reactor 2 Hydraulic Proportioning System | |
---|---|
Maximum Fluid Working Pressure for Bare Proportioners | |
Models H-XP2 and H-XP3 | 3500 psi |
Minimum Fluid Working Pressure for Bare Proportioners | |
H-XP2 | 1200 psi |
H-XP3 | 850 psi |
Fluid: Oil Pressure Ratio | |
Models H-XP2 and H-XP3 | 2.79 : 1 |
Fluid Inlets | |
Component A (ISO) | 3/4 npt(f), 300 psi maximum |
Component B (RES) | 3/4 npt(f), 300 psi maximum |
Fluid Outlets | |
Component A (ISO) | #8 1/2 in. JIC, with #5 5/16 in. JIC adapter |
Component B (RES) | #10 5/8 in. JIC, with #6 3/8 in. JIC adapter |
Fluid Circulation Ports | |
1/4 npsm(m) | 250 psi |
Maximum Fluid Temperature | |
190° F | |
Maximum Output (10 weight oil at ambient temperature) | |
Model H-XP2 | 1.5 gpm (60 Hz) |
Model H-XP3 | 2.8 gpm (60 Hz) |
Output Per Cycle (A and B) | |
Models H-XP2 and H-XP3 | 0.042 gal. |
Line Voltage Options | |
230V 1 phase and 230V 3 phase units: 195–264 Vac, 50/60 Hz | |
400V 3 phase units: 338–457 Vac, 50/60 Hz | |
Amperage Requirement (phase) | |
See the Models listing in the manual. | |
Heater Power (A and B heaters total) | |
See the Models listing in the manual. | |
Hydraulic Reservoir Capacity | |
3.5 gal. | |
Recommended Hydraulic Fluid | |
Citgo, A/W Hydraulic Oil, ISO Grade 46 | |
Sound Power, per ISO 9614–2 | |
90.2 dB(A) | |
Sound Pressure 1 m From Equipment | |
82.6 dB(A) | |
Weight | |
H-XP3, | 600 lb |
H-XP2, 15 kW | 556 lb |
Wetted Parts | |
Aluminum, stainless steel, zinc-plated carbon steel, brass, carbide, chrome, fluoroelastomer, PTFE, ultra-high molecular weight polyethylene, chemically resistant o-rings |