Easy-to-operate variable ratio system - ideal for material manufacturer test labs.
Engineered for specialty materials that require a range or difference in volumetric ratio, the Reactor H-VR allows you to spray ratios from 1:1 to 2.5:1. The system provides infinitely adjustable volume ratio – the operator can dial in the exact volume ratio to adjust the A and B pumps to dispense the correct amount of material.
Reactor H-VR | |
---|---|
Maximum Fluid Working Pressure | 3500 psi |
Fluid Inlets | 3/4 npsm union in 1 in. npt(f) ball valve |
Fluid Circulation Ports | 1/4 npsm(m), with plastic tubing, 250 psi (1.75 MPa, 17.5 bar) maximum |
Maximum Fluid Temperature | 190°F |
Maximum Output ( 10 weight oil at ambient temperature) 1:1 | 3.0 gpm (11.4 liter/min) (60 Hz) |
Output per Cycle (A and B) | Variable: 2 oz.- 5 oz. (60 cc - 150 cc) per pump* |
Stroke Length | Variable: 2 in. - 5 in. (5.08 cm - 12.7 cm) |
Amperage Requirement | See instruction manual. |
Heater Power (A and B heaters total, no hose) | See instruction manual. |
Hydraulic Reservoir Capacity | 3.5 gal |
Recommended Hydraulic Fluid | Citgo A/W Hydraulic Oil, ISO Grade 46 |
Sound Power, measured per ISO 9416–2 | 90.9 dB(A) |
Sound Pressure, measured 1 m from equipment | 84.0 dB(A) |
Weight | 955 lb |
Wetted Parts | Aluminum, stainless steel, zinc-plated carbon steel, brass, carbide, chrome, fluoroelastomer, PTFE, ultra-high molecular weight polyethylene, chemically resistant o-rings |
Line Voltage Requirement | |
230V 3 phase units: | 195-264 Vac, 50/60 Hz |
400V 3 phase units: | 338-457 Vac, 50/60 Hz |
Fluid Outlets | |
Component A (ISO): | #8 (1/2 in.) JIC, with #5 (5/16 in.) JIC adapter |
Component B (RES): | #10 (5/8 in.) JIC, with #6 (3/8 in.) JIC adapter |
Notes | |
* Output example | 2.5:1 ratio = 150 cc (B side):60 cc (A side) |
2.5:1 output = 150 cc (B side) + 60 cc (A side) = 210 cc per cycle | |
All other brand names or marks are used for identification purposes and are trademarks of their respective owners. |